Access the full text.
Sign up today, get DeepDyve free for 14 days.
A. Sinha, Dhanjai, B. Tan, Yujin. Huang, Huimin Zhao, Xueming Dang, Jiping Chen, R. Jain (2018)
MoS2 nanostructures for electrochemical sensing of multidisciplinary targets: A reviewTrends in Analytical Chemistry, 102
D. Bavykin, F. Walsh (2009)
Titanate and Titania Nanotubes
(2011)
Graphene nanosheet: synthesis
Guohai Yang, Chengzhou Zhu, Dan Du, Junjie Zhu, Yuehe Lin (2015)
Graphene-like two-dimensional layered nanomaterials: applications in biosensors and nanomedicine.Nanoscale, 7 34
M. Pumera, A. Loo (2014)
Layered transition-metal dichalcogenides (MoS2 and WS2) for sensing and biosensingTrends in Analytical Chemistry, 61
A. Martins, Christian Harito, D. Bavykin, F. Walsh, M. Lanza (2017)
Insertion of nanostructured titanates into the pores of an anodised TiO2 nanotube array by mechanically stimulated electrophoretic depositionJournal of Materials Chemistry C, 5
Karolina Pecková, H. Ayyildiz, Mustafa Topkafa, H. Kara, M. Ersoz, J. Barek (2007)
Polarographic and Voltammetric Determination of Trace Amounts of 2-AminoanthraquinoneChemia Analityczna, 52
Lianzhou Wang, T. Sasaki (2014)
Titanium oxide nanosheets: graphene analogues with versatile functionalities.Chemical reviews, 114 19
Hubiao Huang, Yulong Ying, Xinsheng Peng (2014)
Graphene oxide nanosheet: an emerging star material for novel separation membranesJournal of Materials Chemistry, 2
(1998)
Osmotic swelling to exfoliation
Mengjun Wang, Zichun Fan, Liqiang Yi, Jiasheng Xu, Xiaobo Zhang, Zhiwei Tong (2018)
Construction of iron porphyrin/titanoniobate nanosheet sensors for the sensitive detection of nitriteJournal of Materials Science, 53
MoS 2 nanostructures for electrochemical sensing of multidisciplinary targets : a review , Trac
(2009)
Electroanalysis in 2 D - TiO 2 nanosheet hosts : electrolyte and selectivity effects in ferroceneboronic acid - saccharide bind
(2008)
Protonic titanate derived from CsxTi 2x / 2 Mgx / 2 O 4 ( x 1⁄4 0 . 7 ) with lepidocrocite - type layered structure
Gerald Manbeck, E. Fujita (2015)
A review of iron and cobalt porphyrins, phthalocyanines and related complexes for electrochemical and photochemical reduction of carbon dioxideJournal of Porphyrins and Phthalocyanines, 19
(2008)
Raman scattering properties of a protonic titanate H x Ti 2-x/4 , O-x/4 H 2 O (x ¼ 0.7) with lepidocrocite-type layered structure
Fengwang Li, D. Macfarlane, Jie Zhang (2018)
Recent advances in the nanoengineering of electrocatalysts for CO2 reduction.Nanoscale, 10 14
Elizabeth Milsom, J. Novák, S. Green, Xiaohang Zhang, Susan Stott, R. Mortimer, K. Edler, F. Marken (2007)
Layer-by-layer deposition of open-pore mesoporous TiO2-Nafion® film electrodesJournal of Solid State Electrochemistry, 11
(2009)
Titanate and Titania Nanotubes: Synthesis
Nobuyuki Sakai, Y. Ebina, K. Takada, T. Sasaki (2004)
Electronic band structure of titania semiconductor nanosheets revealed by electrochemical and photoelectrochemical studies.Journal of the American Chemical Society, 126 18
T. Bruno, P. Svoronos (2020)
Electroanalytical MethodsCRC Handbook of Basic Tables for Chemical Analysis
S. Robledo, V. Zachetti, M. Zón, H. Fernández (2013)
Quantitative determination of tocopherols in edible vegetable oils using electrochemical ultra-microsensors combined with chemometric tools.Talanta, 116
(1992)
Effect of electrolytes concentration on axial anion ligation in manganese(III) mesotetraphenylporphyrin chlorides
Raman scattering properties of a protonic titanate HxTi 2x / 4 , Ox / 4 H 2 O ( x 1⁄4 0 . 7 ) with lepidocrocite - type layered structure
V. Kratochvíl, M. Nepraš (1972)
Anthraquinone dyestuffs. XIV. Protonation of 9,10-anthraquinone derivativesCollection of Czechoslovak Chemical Communications, 37
(2018)
Dhanjai
M. Sýs, B. Švecová, I. Švancara, R. Metelka (2017)
Determination of vitamin E in margarines and edible oils using square wave anodic stripping voltammetry with a glassy carbon paste electrode.Food chemistry, 229
Baiqing Yuan, Chunying Xu, Dehua Deng, Y. Xing, Lin Liu, H. Pang, Daojun Zhang (2013)
Graphene oxide/nickel oxide modified glassy carbon electrode for supercapacitor and nonenzymatic glucose sensorElectrochimica Acta, 88
Christian Harito, D. Bavykin, M. Light, F. Walsh (2017)
Titanate nanotubes and nanosheets as a mechanical reinforcement of water-soluble polyamic acid: Experimental and theoretical studiesComposites Part B-engineering, 124
T. Gao, H. Fjellvåg, P. Norby (2009)
Protonic titanate derived from CsxTi2−x/2Mgx/2O4 (x = 0.7) with lepidocrocite-type layered structureJournal of Materials Chemistry, 19
Yuanyang Rong, R. Malpass‐Evans, M. Carta, N. McKeown, G. Attard, F. Marken (2014)
High density heterogenisation of molecular electrocatalysts in a rigid intrinsically microporous polymer hostElectrochemistry Communications, 46
G. Matricali, M. Dieng, J. Dufeu, M. Guillou (1976)
Etude electrochimique a l'etat solide du couple anthraquinone—9.10—anthraquinol, en tant que matiere active d'electrode de generateur secondaireElectrochimica Acta, 21
K. Lehmann, John Smolarek, O. Khalil, L. Goodman (1979)
Vibrational assignments for the Raman and the phosphorescence spectra of 9,10-anthraquinone and 9,10-anthraquinone-d/sub 8//sup 1/. [Low temperature spectra]The Journal of Physical Chemistry, 83
T. Gao, H. Fjellvåg, P. Norby (2008)
Raman scattering properties of a protonic titanate HxTi2-x/4[symbol: see text]x/4O4.H2O ([symbol: see text], vacancy; x=0.7) with lepidocrocite-type layered structure.The journal of physical chemistry. B, 112 31
C. Banks, T. Davies, R. Evans, G. Hignett, A. Wain, N. Lawrence, J. Wadhawan, F. Marken, R. Compton (2003)
Electrochemistry of immobilised redox droplets: Concepts and applicationsPhysical Chemistry Chemical Physics, 5
T. Sasaki, M. Watanabe (1997)
Semiconductor Nanosheet Crystallites of Quasi-TiO2 and Their Optical PropertiesJournal of Physical Chemistry B, 101
A. Ullah, A. Rauf, U. Rana, R. Qureshi, M. Ashiq, H. Hussain, H. Kraatz, A. Badshah, Afzal Shah (2015)
pH Dependent Electrochemistry of Anthracenediones at a Glassy Carbon ElectrodeJournal of The Electrochemical Society, 162
Shaojun Guo, S. Dong (2011)
Graphene nanosheet: synthesis, molecular engineering, thin film, hybrids, and energy and analytical applications.Chemical Society reviews, 40 5
T. Sasaki (1998)
Molecular nanosheets of quasi-TiO2: preparation and spontaneous reassemblingSupramolecular Science, 5
A. Bond, F. Marken (1994)
Mechanistic aspects of the electron and ion transport processes across the electrode | solid | solvent (electrolyte) interface of microcrystalline decamethylferrocene attached mechanically to a graphite electrodeJournal of Electroanalytical Chemistry, 372
F. Stenman (1969)
Raman Scattering from Powdered 9, 10‐AnthraquinoneJournal of Chemical Physics, 51
M. Ghanem, İ. Koçak, A. Al-Mayouf, M. Alhoshan, P. Bartlett (2012)
Covalent modification of carbon nanotubes with anthraquinone by electrochemical grafting and solid phase synthesisElectrochimica Acta, 68
T. Kondo, K. Sakai, Takeshi Watanabe, Y. Einaga, M. Yuasa (2013)
Electrochemical detection of lipophilic antioxidants with high sensitivity at boron-doped diamond electrodeElectrochimica Acta, 95
L. Devlin, M. Jamal, K. Razeeb (2013)
Novel pH sensor based on anthraquinone–ferrocene modified free standing gold nanowire array electrodeAnalytical Methods, 5
A. Wain, J. Wadhawan, R. Compton (2004)
Biphasic redox chemistry of α-tocopherol: Evidence for electrochemically induced hydrolysis and dimerization on the surface of and within femtolitre droplets immobilized onto graphite electrodesPhysical Chemistry Chemical Physics, 6
(1979)
Vibrational assignments for the Raman and phosphorescence spectra of 9,10-anthraquinone and 9,10-anthraquinone-d 8
D. Bavykin, F. Walsh (2007)
Kinetics of Alkali Metal Ion Exchange into Nanotubular and Nanofibrous TitanatesJournal of Physical Chemistry C, 111
F. Marken, J. Watkins, A. Collins (2011)
Ion-transfer- and photo-electrochemistry at liquid|liquid|solid electrode triple phase boundary junctions: perspectives.Physical chemistry chemical physics : PCCP, 13 21
S. Jeoung, Dongho Kim, D. Cho (2000)
Transient resonance Raman spectroscopic studies of some paramagnetic metalloporphyrins: effects of axial ligand on charge‐transfer and photoreduction processesJournal of Raman Spectroscopy, 31
T. Sasaki, Y. Ebina, and Kitami, M. Watanabe, T. Oikawa (2001)
Two-Dimensional Diffraction of Molecular Nanosheet Crystallites of Titanium OxideJournal of Physical Chemistry B, 105
G. Foran, R. Armstrong, M. Crossley, P. Lay (1992)
Effect of electrolyte concentration on axial anion ligation in manganese(III) meso-tetraphenylporphyrin chloridesInorganic Chemistry, 31
W. Wahyuni, B. Putra, Christian Harito, D. Bavykin, F. Walsh, T. James, G. Kociok‐Köhn, F. Marken (2018)
Electroanalysis in 2D-TiO2 Nanosheet Hosts: Electrolyte and Selectivity Effects in Ferroceneboronic Acid – Saccharide BindingElectroanalysis, 30
T. Sasaki, M. Watanabe (1998)
Osmotic Swelling to Exfoliation. Exceptionally High Degrees of Hydration of a Layered TitanateJournal of the American Chemical Society, 120
Marie Coatanea, A. Darchen, D. Hauchard (2001)
Electroanalysis at ultramicroelectrodes of oils and fatsSensors and Actuators B-chemical, 76
F. Marken, J. Watkins, K. Lawrence, James Taylor, T. James, S. Bull (2011)
Carbon Nanoparticle Surface Electrochemistry: High-Density Covalent Immobilisation and Pore-ReactiviElectroanalysis
M. Ghanem, R. Compton, B. Coles, A. Canals, F. Marken (2005)
Microwave enhanced electroanalysis of formulations: processes in micellar media at glassy carbon and at platinum electrodes.The Analyst, 130 10
(1976)
10-anthraquinone-anthraquinol couple e use in negative electrodereactions of secondary electrochemical generators
Po Wang, Zhibin Mai, Zong Dai, Yongxin Li, Xiaoyong Zou (2009)
Construction of Au nanoparticles on choline chloride modified glassy carbon electrode for sensitive detection of nitrite.Biosensors & bioelectronics, 24 11
D. Bavykin, J. Friedrich, F. Walsh (2006)
Protonated Titanates and TiO2 Nanostructured Materials: Synthesis, Properties, and ApplicationsAdvanced Materials, 18
Gregory Wildgoose, M. Pandurangappa, N. Lawrence, Li Jiang, T. Jones, R. Compton (2003)
Anthraquinone-derivatised carbon powder: reagentless voltammetric pH electrodes.Talanta, 60 5
R. Gaughan, D. Shriver, L. Boucher (1975)
Resonance raman spectra of manganese (III) tetraphenylporphin halides.Proceedings of the National Academy of Sciences of the United States of America, 72 2
(2015)
Recent advances in two-dimensional nanostructures for catalysis applications
T. Sasaki, M. Watanabe, H. Hashizume, H. Yamada, H. Nakazawa (1996)
Macromolecule-like Aspects for a Colloidal Suspension of an Exfoliated Titanate. Pairwise Association of Nanosheets and Dynamic Reassembling Process Initiated from ItJournal of the American Chemical Society, 118
A. Sinha, Dhanjai, Huimin Zhao, Yujin. Huang, Xianbo Lu, Jiping Chen, R. Jain (2018)
MXene: An emerging material for sensing and biosensingTrAC Trends in Analytical Chemistry
C. Costentin, M. Robert, J. Savéant (2017)
Molecular Catalysis of Electrochemical ReactionsElements of Molecular and Biomolecular Electrochemistry
J. Beattie, Ciaran Maguire, S. Gilchrist, Lindsay Barrett, C. Cross, F. Possmayer, M. Ennis, J. Elborn, W. Curry, J. McGarvey, B. Schock (2007)
The use of Raman microscopy to determine and localize vitamin E in biological samplesThe FASEB Journal, 21
M. Bonné, C. Reynolds, Stuart Yates, G. Shul, Joanna Niedziółka, M. Opallo, F. Marken (2006)
The electrochemical ion-transfer reactivity of porphyrinato metal complexes in 4-(3-phenylpropyl)pyridine | water systemsNew Journal of Chemistry, 30
Weifang Yao, H. Peng, R. Webster (2009)
Electrochemistry of α-Tocopherol (Vitamin E) and α-Tocopherol Quinone Films Deposited on Electrode Surfaces in the Presence and Absence of Lipid MultilayersJournal of Physical Chemistry C, 113
Analytica Chimica Acta: X 1 (2019) 100001 Contents lists available at ScienceDirect Analytica Chimica Acta: X journal homepage: www.journals.elsevier.com/analytica-chimica-acta-x Extraction of hydrophobic analytes from organic solution into a titanate 2D-nanosheet host: Electroanalytical perspectives a, b a, b c c Wulan Tri Wahyuni , Budi Riza Putra , Christian Harito , Dmitry V. Bavykin , c d a, * Frank C. Walsh , Philip J. Fletcher , Frank Marken Department of Chemistry, University of Bath, Claverton Down, BA2 7AY, Bath, UK Department of Chemistry, Faculty of Mathematics and Natural Sciences, Bogor Agricultural University, Bogor, West Java, Indonesia Energy Technology Research Group, Faculty of Engineering and Physical Sciences of Southampton, SO17 1BJ, Southampton, UK Materials and Chemical Characterisation Facility (MC2), University of Bath, Claverton Down, BA2 7AY, Bath, UK art i cle i nfo abstract Article history: Titanate nanosheets (single layer, typically 200 nm lateral size) deposited from aqueous colloidal solution Received 22 October 2018 onto electrode surfaces form lamellar hosts that bind redox active molecular redox probes. Here, hy- Received in revised form drophobic redox systems such as anthraquinone, 1-amino-anthraquinone, deca-methylferrocene, 2 December 2018 5,10,15,20-tetraphenyl-21H,23H-porphine manganese (III) chloride (TPPMnCl), and a-tocopherol are Accepted 10 December 2018 shown to bind directly from cyclopentanone solution (and from other types of organic solvents) into the Available online 16 December 2018 titanate nanosheet film. For anthraquinone derivatives, stable voltammetric responses are observed in aqueous media consistent with 2-electron 2-proton reduction, however, independent of the pH of the Keywords: outside solution phase environments. For decamethylferrocene a gradual decay of the voltammetric 2D-nanosheet response is observed, but for TPPMnCl a more stable voltammetric signal is seen when immersed in Microphase chloride containing (NaCl) electrolyte. a-Tocopherol exhibits chemically irreversible oxidation and is Hydrophobicity Electrocatalysis detected with 1 mMe20 mM linear range and approximately 10 M concentration limit of detection. All Sensor redox processes exhibit an increase in current with increasing titanate film thickness and with increasing Membrane external electrolyte concentration. This and other observations suggest that important factors are analyte concentration and mobility within the titanate host, as well as ion exchange between titanate nano- sheets and the outside electrolyte phase to maintain electroneutrality during voltammetric experiments. The lamellar titanate (with embedded tetrabutyl-ammonium cations) behaves like a hydrophobic host (for hydrophobic redox systems) similar to hydrophobic organic microphase systems. Potential for analytical applications is discussed. © 2018 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). 1. Introduction [7], catalytic reactions can occur [8], or analytical detection can be performed [9]. Tong and coworkers demonstrated catalytic nitrite Modified electrodes provide an important tool in sensor sensing with an iron porphyrin/titanoniobate nanosheet composite development [1]. There is considerable interest in new types of 2D- modified electrode [10]. In a recent study, we investigated the nanosheet materials with new properties that can contribute to the immobilisation and reactivity of ferrocene boronic acid as molec- development of new analytical procedures based on modified ular receptor for glucose or fructose in titanate nanosheet hosts electrodes. Recent progress has been made, for example, in the [11]. Titanates and titanate nanosheets provide an important class development of graphene derivatives [2], MXenes [3], metal chal- of materials [12,13] and they are highly negatively charged. Binding cogenides [4,5], and other types of lamellar 2D-oxides [6]. Nano- and exchange of cations is a well known pattern of reactivity for sheet architectures provide a high level of surface exposure and titanates [14]. Films can be deposited onto electrodes directly from inter-lamellar spaces, within which catalysts can be immobilised aqueous colloidal solution. The inorganic nature of the titanates may suggest that inter-lamellar space in titanate nanosheet de- posits should be highly polar and hydrophilic. However, it is shown here that titanate deposits in fact show behaviour more closely * Corresponding author. related to hydrophobic hosts. It is suggested that the nature of the E-mail address: f.marken@bath.ac.uk (F. Marken). https://doi.org/10.1016/j.acax.2018.100001 2590-1346/© 2018 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). 2 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 associated cations (here tetrabutylammonium in the titanate film) amino-anthraquinone, decamethylferrocene, tetraphenylporphy could be a factor affecting the reactivity and swelling of titanate rinato-Mn(III)chloride (TPPMnCl), and a-tocopherol are extracted nanosheet coatings when immersed in different types of liquid directly from an organic solution phase into the titanate film media. (deposited on a glassy carbon electrode). The type of organic sol- Titanate nanosheet materials have been pioneered and devel- vent and the concentration are shown to affect the extraction oped by Sasaki and coworkers [15e17]. A molten salt reaction was process and the resulting voltammetric behaviour. The effects of employed to produce an intermediate lepidocrocite-like caesium aqueous electrolyte and pH are considered and a model is devel- titanate (Cs Ti , O ), which after cation exchange in acid oped to explain the behaviour of these immobilised redox systems. 0.7 1.825 0.175 4 and alkylammonium (e.g. tetrabutylammonium) cations exfoliates The process of extraction of analyte from organic solution followed to smectictite-like acidic titanate of composition by detection in aquoues electrolyte could be of interest in analytical H Ti , O H O) [18]. A colloidal solution is obtained with procedures. However, both the fundamental understanding and 0.7 1.825 0.175 4 2 sheets of typically 200 nm size and a nominal thickness of 1.3 nm or analytical sensitivity of processes will have to be further improved. a single unit cell [19]. This colloidal material is readily converted into new hybrid materials [20] and nano-composites [21], and 2. Experimental when deposited onto glassy carbon electrodes, it gives films with lamellar structure. Lamellae only merge back into solid bulk 2.1. Chemical reagents structures, when heated to temperatures much higher than ambient. This titanate coating has the ability to bind and retain Titanate nanosheet material was synthesized as describe pre- inter-lamellar redox active molecules and it allows ion uptake and viously by Sasaki [24] and by Harito et al. [20]. Anthraquinone transport in between nanosheets to sustain redox processes at the (molecular weight 208.21 g mol ; CAS: 84-65-1; 97%), 1-amino- electrode surface (Fig. 1). anthraquinone (molecular weight 223.23 g mol ; CAS: 82-45-1; Ion transport and membrane properties of 2D nanosheet mate- 97%), decamethylferrocene (molecular weight 326.30 g mol ; CAS: rials are of considerable interest [22]. The presence of negative charge 12126-50-0; 97%), 5,10,15,20-tetraphenyl-21H,23H-porphine man- on the titanate (as indicated by the negative zeta potential) requires ganese (III) chloride (TPPMnCl; molecular weight 703.11 g mol ; the presence of counter cations (here indicated as tetrabutylammo- CAS: 32195-55-4; 95%), and ±a-tocopherol (molecular weight nium cations). This introduces ion conductivity and exchange as well 430.71 g mol ; CAS: 10191-41-0; 96%) were obtained from as a degree of semi-permeability depending on the interaction with Sigma-Aldrich. Sodium dihydrogen phosphate and sodium phos- the external electrolyte. When immobilising a redox active molecule phate dibasic hexa-hydrate (for buffer preparation), sodium chlo- into the titanate layers and when applying a potential to switch the ride, cyclopentanone, acetone, chloroform, dichloromethane, and redox state (immersed in aqueous electrolyte), ion transfer or ex- ethanol were purchased from Sigma-Aldrich, Fisher Scientific, or change at the titanate nanosheet j aqueous electrolyte interface is VWR BDH Chemicals and used without further purification. Solu- required to balance the charges (to maintain electroneutrality). For tions were prepared under ambient condition in volumetric flasks related microphase redox processes (e.g. based on immobilised oil with ultrapure water with resistivity of 18.2 MOhm cm (at 22 C, microdroplets at electrode surfaces [23]) coupled electron transfer from an ELGA Purelab Classic system). and ion exchange has been investigated with voltammetric methods. Conditions within the microphase deposit depend on the type of 2.2. Instrumentation cation or anion that transfers at the interface. It is shown here that also for titanate nanosheet deposits ion exchange across the titana- A classic three-electrodes system controlled with a micro- tejaqueous electrolyte interface is important. Autolab III system (Metrohm-Autolab, Netherlands) with NOVA Here, the behaviour of titanate nanosheet deposits is investi- 2.1.2 software was used for cyclic voltammetry measurement. The gated for several hydrophobic redox systems. Anthraquinone, 1- counter and reference electrodes were platinum wire and Ag/AgCl Fig. 1. Schematic drawing of the titanate nanosheet exfoliated with tertrabutylammonium cations and re-deposited from colloidal aqueous solution onto a glassy carbon electrode. This deposit is then investigated as sorbent and host for hydrophobic redox systems (bound from organic solution) and for electrochemical reactivity (when immersed in aqueous electrolyte media). W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 3 in 3 M NaCl (from BASi). The working electrode was a 3.0 mm- diameter glassy carbon electrode (GCE from BASi) modified by coating with a titanate nanosheet film. Characterization of titanate nanosheet materials was carried out using Transmission Electron Microscopy (TEM) analysis (JEOL JEM-2100Plus). The thickness of titanate nanosheet films on glassy carbon was analysed using cross- sectional Scanning Electron Microscopy (SEM, JEOL JSM6480LV) after freeze-fracture. Raman spectroscopy analysis of pure titanate films and film with embedded extracted hydrophobic redox sys- tems were performed on a Renishaw inVia confocal microscope system. 2.3. Procedures Electrode modification. The glassy carbon electrode (GCE, 3.0 mm diameter, BSAi) was polished with alumina slurry (Buehler, 0.3 mm) and cleaned with isopropanol and filtered water before modification. An aliquot of 4 or 8 mL titanate nanosheet colloidal solution (2.56 g L ) was deposited onto the electrode surface by drop casting. The solution was dried at ambient temperature forming thin visible (opaque-white) films of titanate nanosheets. Fig. 2 shows TEM data for titanate nanosheets, typical diffraction data for titanate nanosheet assemblies [16], and cross-sectional SEM data for 4 mL and 8 mL deposits with approximately 1.9 mm and 3.3 mm thickness. Electron diffraction pattern are consistent with diffraction data for a lamellar system as reported initially by Sasaki et al. [16]. The distinct widening and stabilisation of the inter-lamellar space with the intercalaction of bulky organic exfo- liation cations has been reported [25]. Extraction of redox-active analytes. Redox-active analytes solution were prepared in cyclopentanone (or in other types of organic solvents such as ethanol, chloroform, dichloromethane, or acetone). The glassy carbon electrode modified with titanate nanosheet film was immersed into the solutions (for a defined period of time) to allow the extraction of redox-active analytes from its solution into the titanate nanosheet film. After immersion the electrode was dried under ambient conditions. Electrochemical and zeta-potential measurements. Electro- chemical measurements were carried out after immersion of the modified electrode into aqueous electrolyte solution. The zeta- potential for the colloidal titanate solution in water was measured on a Zetasizer Nano ZS (Malvern Instruments Ltd, Mal- -1 -1 vern, UK) for 0.25 gL (33.9 mV)), for 0.025 gL (32.4 mV), and -1 for 0.0025 gL (31.2 mV) to give an average of 32.5 mV consis- tent with an overall negative charge before deposition. Raman measurements. An aliquot of 4 mL titanate nanosheet colloidal solution (2.56 g L ) was deposited on to silicon wafer surface by drop casting method. The solution was dried at ambient temperature forming thin film of titanate nanosheets. Raman spectroscopy analysis of titanate nanosheet film was performed on a Renishaw inVia system with the following condition, detector: CCD Camera 1040 256; Laser: 532 nm; Grating: 1800 mm (532 nm); Exposure time: 10 s 30 accumulations; Laser power: 1%; Center: 1033 Raman shift/cm ; Objective 50. 3. Results and discussion Fig. 2. (A) Transmission electron microscopy (TEM) image of titanate nanosheet ma- terial. (B) Electron diffraction pattern showing the main diffraction lines for the stacks 3.1. Binding of anthraquinone derivatives into a titanate nanosheet of nanosheets with approximately 1.8 nm inter-nanosheet gap. (C) Scanning electron host microscopy (SEM) images for films deposits of titanate nanosheet films of approxi- mately 1.9 mm and 3.3 mm thickness. Anthraquinone may be regarded as a model hydrophobic redox system with very low solubility in aqueous media and good elec- trochemical reactivity in contact to aqueous electrolyte [26]. The Anthraquinone is reduced in a 2-electron 2-proton process (Equa- wider class of anthracenediones is widely used in industry and tion 1) to the corresponding anthraquinol (see reaction equation in Fig. 3) and has been used, for example, as a probe for local pH in domestic products and commercially significant [27]. 4 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 aqueous media [28]. When immobilised at an electrode surface the electrode. Electrodes were prepared by initially coating titanate voltammetric peak feature for the anthraquinone reduction would nanosheets onto the glassy carbon electrode. This electrode is then usually exhibit a Nernstian shift of 2.303 RT/F per pH unit change in immersed for 60 min into a solution of 2.5 mM anthraquinone in aqueous pH (or approximately 58 mV/pH at room temperature or cyclopentanone, removed and dried. The resulting modified elec- 22 C[29]). trode clearly shows the voltammetric response consistent with the reduction of anthraquinone in aqueous phosphate buffer solution environment. The midpoint potential of ca. 0.43 V vs. Ag/AgCl is consistent with that reported for anthraquinone in aqueous media and also for surface immobilised anthraquinone moities [30,31]. Most reports show a slightly more negative E under similar mid conditions and a Nernstian response to pH changes [32]. However, in the case of titanate immobilised anthraquinone, the pH depen- dence of the voltammetric signal is suppressed (vide infra). Fig. 3A shows typical voltammetric responses for anthraquinone Data in Fig. 3A are shown for two different loadings of titanate immobilised into a film of titanate nanosheets on a glassy carbon Fig. 3. (A) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for anthraquinone extracted from 2.5 mM solution in cyclopentanone at (i) 1.9 mm thickness titanate film modified GCE and (ii) 3.3 mm thickness titanate film modified GCE, (B) Cyclic voltammogram (scan rate (i) 1, (ii) 0.75, (iii) 0.5, (iv) 0.25, (v) 0.1, (vi) 0.075, (vii) 0.05, (viii) -1 0.025, (ix) 0.01 Vs ; in 0.1 M phosphate buffer pH 7) for anthraquinone extracted from 2.5 mM solution in cyclopentanone at 1.9 mm thickness titanate film modified GCE. (C) Plot of anodic and cathodic peak currents versus scan rate (estimated error 10%). (D) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer (i) pH 7, (ii) pH 9, (iii) pH 10, (iv) pH 11) for anthraquinone extracted from 2.5 mM solution in cyclopentanone at 1.9 mm thickness titanate film modified GCE. (E) Plot of peak current versus concentration of 1 3 anthraquinone in cyclopentanone solution (estimated error 10%). The line shows a Langmuir isotherm fitting with an approximate binding constant of K ¼ 2000 mol dm . W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 5 nanosheets on the glassy carbon electrode surface (films of tetrabuylammonium cations from the titanate exfoliation process). approximately 1.9 mm and 3.3 mm thickness) and a clear increase in Swelling of the titanate nanosheets in different types of solvents the peak current for both reduction and oxidation occurs when could be important to allow uptake of redox active species. Even increasing the titanate film thickness. This was confirmed by more striking is the effect of the supporting electrolyte concen- additional experiments (not shown) employing deposition of the tration in the aqueous phase on the voltammetric response for same mass of titanate nanosheets and extending the deposit over 2.5 mM anthraquinone absorbed from cyclopentanone (Fig. 4B). the outside insulator of the electrode (thereby thinning the coating With increasing NaCl electrolyte concentration, the voltammetric over the electrode). Titanate nanosheet material present outside of response systematically increases. This suggests that anthraqui- the glassy carbon perimeter is inactive and therefore not respon- none bound into titanate nanosheet deposit is not fully converted, sible for voltammetric responses. Therefore, the film thickness for and that only a thin layer containing anthraquinone close to the titanate nanosheet deposits on the glassy carbon surface is the key surface of the electrode is electrochemically active. The higher NaCl to further enhancement of the voltammetric signal. This observa- electrolyte concentration may lead to more partitioning of NaCl tion could suggest that diffusion (transport) of anthraquinone (and therefore additional chloride anions) into the titanate nano- within the film occurs in the given time frame and space. The sheet film and this could be the underlying reason for the increase diffusion layer can be linked to the diffusion coefficient (by in the current signal (explaining both, the electrolyte concentration vFd dimensional analysis) to give D ¼ [33], which can be esti- effect and film thickness effect). Therefore, a limiting factor in the app RT 9 2 1 mated here (see Fig. 3C) as D ¼ 0.04 10 m s or faster. voltammetric response could be “internal excess electrolyte” app Therefore, the anthraquinone molecule in oxidised and reduced form could have considerable mobility within the titanate nano- sheet host material to explain the observations. This considerable level of mobility could be linked to the presence of organic cations within the lamella structure (see Fig. 1). However, more likely in this case is that another species (an electrolyte counter ion) is responsible for the apparent diffusion process and the magnitude of the voltammetric response. Anthraquinone is in fact reactive only very close to the electrode surface with much lower rates of diffusion within the titanate host (vide infra). When investigating the effect of scan rate (see Fig. 3B and C) in cyclic voltammograms for immobilised anthraquinone, the antici- pated increase with square root of scan rate (for a diffusion controlled case) can be seen, but the peak shapes are more complex for this simple relationship to hold. Fig. 3D shows data for the reduction of anthraquinone immobilised in titanate nanosheets at different pH values (all in 0.1 M phosphate buffer and for freshly prepared electrodes). The absence of a significant pH shift is striking and indicative of a mechanism that does not include proton or hydroxide exchange across the titanate nanosheet j aqueous electrolyte phase boundary. Other types of ions may be involved. In this particular case “excess electrolyte anions” within the lamella space are suggested to undergo expulsion during anthraquinone reduction (vide infra). The effect of anthraquinone concentration in the cyclo- pentanone solution was investigated over a range from 0.1 to 10 mM (see Fig. 3E). The plot of peak current versus concentration reveals an initial increase with concentration followed by a plateau. The data set can be fitted based on the simplistic model of a 1 3 Langmuir isotherm with a binding constant K ¼ 2000 mol dm . However, this interpretation is likely to be wrong and the under- lying mechanisms for binding is unlikely to lead to saturation. For both, binding and electrochemical conversion, there is more complexity as is revealed in data shown in Fig. 4. The reason for the plateau in peak currents here is suggested to be linked not to the availability of binding sites, but instead to a limited amount of “excess electrolyte anions” undergoing expulsion into the aqueous phase during anthraquinone reduction. This can explain both, the observed titanate film thickness effects on voltammetric responses and the absence of pH effects on voltammetric signals for anthraquinone. When investigating the effects of different organic solvents on 1 Fig. 4. A) Cyclic voltammogram (scan rate 100 mV s ; in 0.1 M phosphate buffer pH 7) the anthraquinone binding process (see Fig. 4A), considerable ef- for anthraquinone extracted from 2.5 mM solution in (i) cyclopentanone, (ii) acetone, (iii) chloroform, (iv) dichloromethane solution at 1.9 mm thickness titanate film fects are observed when comparing (i) cyclopentanone, (ii) acetone, modified GCE, (B) Cyclic voltammogram (scan rate 100 mV s ; in (i) 0.1, (ii) 0.5, (iii) (iii) chloroform, and (iv) dichloromethane. The process appears to 1 M NaCl) for anthraquinone extracted from 2.5 mM solution in cyclopentanone at be working particularly well for anthraquinone in cyclopentanone, 1.9 mm thickness titanate film modified GCE. (C) Raman spectra of pure titanate film although reasons for this behaviour are currently not fully under- (blue) and film with absorbed anthraquinone (orange). The * symbols indicates a sil- stood (although likely to be linked to the presence of icon substrate signal. 6 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 within the titanate nanosheet material. The plateau region in the Fig. 5D shows the plot of peak current data versus 1-amino- plot in Fig. 3E could be associated with amount of internal free anthraquinone concentration clearly revealing the initial increase electrolyte (in this case mobile chloride anions that are expelled followed by a plateau. It seems likely that here again the reduction from the titanate host during reduction). In addition, the observed of 1-amino-anthraquinone is limited by “internal excess electro- D for anthraquinone (vide supra) could then be linked to elec- lyte” rather than by the amount of 1-amino-anthraquinone bound app trolyte mobility and to a lesser extent to mobility of anthraquinone. into the titanate nanosheet host material. This is confirmed by the In order to obtain additional evidence for the presence of coloration of the titanate nanosheet material after immersion into anthraquinone in the titanate nanosheet film material, additional the red-coloured 1-amino-anthraquinone (see Fig. 5C). With Raman spectroscopy experiments were performed. Fig. 4C shows 30 min deposition time a clear coloration develops indicative of a data for the pure titanate material and for the film with anthra- substantial amount of 1-amino-anthraquinone in the titanate quinone absorbed from 2.5 mM anthraquinone in cyclopentanone nanosheet host. It seems likely that only a small fraction of this (60 min immersion). It can be seen that several strong Raman peaks material (close to the electrode) is converted in the electrochemical are seen at 140, 280, 450, and 705 cm , consistent with previously reduction and the voltammetric reduction peaks are associated reported Raman signals for example for Cs Ti , O [34,35]. with chloride expulsion from the titanate nanosheet deposit. x 2-x/4 x/4 4 Only one new peak associated with the presence of anthraquinone Raman data were not obtained due to strong fluorescence of the 1- at approximately 1650 cm is detected in this wave number range amino-anthraquinone. consistent with this being the first stronger Raman signal associ- ated with C]O stretching for anthraquinone [36,37]. Further experimental data were obtained with a coloured de- rivative of anthraquinone. The anthraquinone derivative 1-amino- anthraquinone is known to be toxic and present in industrial wastes, where it can be detected, for example, by voltammetry or by polarography [38]. The pK for the amino group is 1.19 [39] and therefore this molecule remains uncharged and similar in solubility and behaviour compared to that of the parent anthraquinone. 3.2. Binding of decamethylferrocene into a titanate nanosheet host Data in Fig. 5A shows typical voltammograms for the reduction of 1-amino-anthraquinone absorbed from 2.5 mM solution in Next, a wider range of redox active guest species are considered cyclopentanone in two thicknesses of titanate nanosheet deposits. with the common feature of being soluble in organic solution and Very similar behaviour compared to that observed for anthraqui- insoluble in aqueous electrolyte media. Decamethylferrocene offers none (see Fig. 3) suggests very similar underlying reactions. The a 1-electron redox system (see equation 3) with minimal compli- reduction is likely to follow a 2-electron 2-proton pathway (see cations from chemical reactivity. Previous studies have shown that equation 2). Fig. 5B shows data for voltammetry experiments per- decamethylferrocene is water-insoluble and chemically stable and formed in 0.1 M, 0.5 M, and in 1.0 M aqueous NaCl solution and the readily oxidised with a (anion-dependent) midpoint potential close increase of current with ionic strength is again clearly observed. to 0.0 V vs. Ag/AgCl [40]. Fig. 5. (A) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for 1-aminoanthraquinone extracted from 2.5 mM solution in cyclopentanone at (i) 1.9 mm thickness titanate film modified GCE and (ii) 3.3 mm thickness titanate film modified GCE. (B) Cyclic voltammogram (scan rate 100 mV s ; in (i) 0.1, (ii) 0.5, (iii) 1 M NaCl) for 1- aminoanthraquinone extracted from 2.5 mM solution in cyclopentanone at 1.9 mm thickness titanate film modified GCE. (C) Coloration as a function of time for the titanate film after immersion into the red-coloured 1-amino-anthraquinone. (D) Plot of anodic and cathodic peak currents versus concentration of 1-aminoanthraquinone in cyclopentanone solution (estimated error 10%). W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 7 3.3. Binding of TetraphenylporphyrinatoMn(III)Cl into a titanate nanosheet host Phorphyrin metal complexes are well known catalysts and electro-catalysts and therefore often immobilised into host mate- rials [41,42]. Recently, tetraphenylporphyrin-Fe(III) complexes were immobilised into polymers of intrinsic microporosity to act as immobilised electrocatalysts at glassy carbon electrodes [43]. Here, the immobilisation and reactivity of tetraphenylporphyrin-Mn(III) Cl (or (TPPMnCl) into titanate nanosheet films is investigated. Fig. 6A shows typical data when the potential is cycled over nine There have been several previous reports for TPPMnCl immobili- consecutive potential cycles. A considerable decrease in the vol- sation and redox cycling in oil microdroplet deposits at electrode tammetric response is observed, but the position of oxidation and surfaces [44]. reduction signal are consistent with the decamethylferrocene/ Data for TPPMnCl immobilised into titanate nanosheet films is decamethylferricenium redox system (see Fig. 6). The observed summarised in Fig. 7. TPPMnCl is soluble in cyclopentanone giving a gradual loss of signal is likely to be associated with slow loss of the dark green coloration. When employing a 2.5 mM TPPMnCl solu- slightly water-soluble decamethylferricenium cation into the tion and immersing a titanate nanosheet film, a colour change from aqueous solution phase (or away from the electrochemical reaction white to green can be observed gradually over 30 min (see Fig. 7F). zone). Data in Fig. 6B demonstrate the effect of titanate nanosheet The voltammetric response for the immobilised TPPMnCl was first host film thickness. Again, the increase in thickness appears to in- investigated immersed in aqueous 0.1 M phosphate buffer at pH 7. crease the peak currents for the voltammetric response. When Fig. 7A shows consecutive voltammetric signals recorded at a scan systematically changing the concentration of the deca- rate of 100 mVs . A reduction of TPPMnCl occurs followed by re- methylferrocene in cyclopentanone an increase in peak currents for oxidation consistent with a one-electron process (Mn(III/II), see both oxidation and reduction (first potential cycles, Fig. 6C and D) equation 4 with L ¼ Cl and L ¼ H O). A decrease in voltammetric 1 2 2 are observed. There is no clear plateau possibly due to cation signal occurs most likely due to a chemical change such as the loss expulsion during oxidation (not anion expulsion as in the case of (or exchange) of the chloro-ligand upon reduction to TPPMn(II). anthraquinone reduction). In the Raman data (Fig. 6E) a rich set of Additional experiments were performed by intentionally adding vibrational peaks are seen for decamethylferrocene (ii) in addition NaCl into the aqueous phosphate buffer solution, but without to those for the titanate nanosheet host signals (i). Fig. 6. (A) Cyclic voltammogram (nine continuous cycles; scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for decamethylferrocene extracted from 40 mM solution in cyclopentanone into a 1.9 mm thickness titanate film modified GCE. (B) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for decamethylferrocene extracted from 2.5 mM solution in cyclopentanone at (i) 1.9 mm thickness titanate film modified GCE and (ii) 3.3 mm thickness titanate film modified GCE. (C) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for decamethylferrocene extracted from (i) 5, (ii) 10, (iii) 20, (iv) 40, (v) 60, (vi) 80, and (vii) 100 mM solution in cyclo- pentanone at 1.9 mm thickness titanate film modified GCE. (D) Plot of peak current versus concentration of decamethylferrocene in cyclopentanone solution (estimated error 10%). (E) Raman spectra of a pure titanate film (i blue) and a film with absorbed decamethylferrocene (ii, orange). The * symbols indicates a silicon substrate signal. 8 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 significant improvement in the signal stability. However, when response is observed with consecutive potential cycles (see Fig. 7C). performing the cyclic voltammetry experiment in the absence of The increase in current is reminiscent to increasing current re- phosphate and directly in aqueous 1 M NaCl (see Fig. 7B), the vol- sponses in higher concentration of electrolyte, as seen for example tammetric response remains more stable. This can be attributed to for anthraquinone. In addition, there is a drift in the voltammetric the absence of phosphate as nucleophile and the presence of suf- responses with increasing potential cycle number to more negative ficiently high concentrations of chloride within the inter-lamellar potentials. This drift in potential could be indicative of a salt ex- space to prevent loss of chloride from the reduced TPPMn(II)Cl change process accompanying redox cycling over time, possibly complex. In further experiments in aqueous 2 M NaCl a higher linked to a change in the interfacial potential at the titanate current response is seen and even an increase in the voltammetric nanosheet j aqueous electrolyte interface (vide infra). The improved Fig. 7. (A) Cyclic voltammogram (twenty continuous cycles; scan rate 100 mV s ) for TPPMnCl extracted from 8 mM solution in cyclopentanone at 1.9 mm thickness titanate film modified GCE in 0.1 M phosphate buffer pH 7 as electrolyte. (B) As before in 1 M NaCl solution as electrolyte. (C) As before in 2 M NaCl solution as electrolyte. (D) Cyclic vol- tammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for TPPMnCl extracted from (i) 1, (ii) 2, (iii) 4, (iv) 6, (v) 8 mM solution in cyclopentanone at 1.9 mm thickness titanate film modified GCE. (E) Plot of peak current versus concentration of TPPMnCl bound from cyclopentanone solution (estimated error 10%). (F) Coloration as a function of time of the titanate film after immersion into the 2.5 mM green-coloured TPPMnCl solution in cyclopentanone. (G) Raman spectra of a pure titanate film (i, blue) and film with absorbed TPPMnCl (ii, orange). The * symbols indicates a silicon substrate signal. W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 9 stability of the voltammetric response for TPPMnCl in the presence the a-tocopherol immobilised into titanate nanosheet films only of chloride containing electrolyte can be linked to the presence of leads to minor changes in spectra with new broad bands at 1 1 1 excess chloride in the titanate film to prevent chloro-ligand sub- approximately 1500 cm and at 1800 cm . The band at 1500 cm stitution (a process known for TPPMn(II)Cl in organic media [45]). appears to be linked to a-tocopherol Raman spectra obtained in the When changing the concentration of TPPMnCl in cyclopentanone pure compound [55]. (see Fig. 7D and E) a systematic increase in voltammetric peak current is observed with an apparent plateau being reached may be 3.5. Binding and reactivity of redox active species in a titanate at about 8 mM solution. nanosheet host To summarise observations, it is possible to extract some gen- eral conclusions and mechanistic information from the data re- ported in this study. Highly hydrophobic redox active species are bound from organic solvents into titanate nanosheet host mate- rials. This is likely to happen via a swelling process (compare [20]), in which the organic solvent enters the titanate inter-layer spacing Raman data for pure titanate nanosheets and for TPPMnCl and in this way allows slow ingress of the redox active guest. This bound into titanate nanosheets are shown in Fig. 7G. Significant explains the effect of the nature of the organic solvent on the bands for embedded TPPMnCl are seen at approximately 1350 cm process. Evaporation of the organic solvent leaves the redox system and around 1500 cm . The latter group of peaks could be related to immobilised in the deposited titanate film. Raman peaks observed previously in organic solution [46]. The The titanate nanosheet films compare in behaviour to hydro- band at 1350 cm could be related to data reported for resonance phobic oil microdroplet deposits containing redox active hydro- Raman measurements in different solvents [47]. phobic guests [56] with coupled electron transfer (at the titanate nanosheet j electrode interface) and ion transfer (at the titanate 3.4. Binding of a-tocopherol derivatives into a titanate nanosheet nanosheet j electrolyte solution interface). The apparent hydro- host phobic behaviour of titanate nanosheets is probably attributed to tetrabutylammonium cation derivatization of the surface of the An analytically relevant redox system is a-tocopherol (or nanosheets during the delapidation process. The electrochemical vitamin E), which occurs naturally [48] and in domestic and conversion of the hydrophobic guest species is likely to occur in a pharmaceutical formulations [49]. a-Tocopherol is highly water- very thin layer close to the electrodes surface (see Fig. 9). Very slow insoluble (see molecular structure in Fig. 8) and acts as anti- diffusion of these molecules within a thin diffusion layer before and oxidant. Electrochemical properties have been investigated in after conversion seems plausible. Bigger molecules such as organic solution [50,51] and for the oil phase surrounded by TPPMnCl show markedly lower currents consistent with lower aqueous electrolyte [52] and for aqueous microemulsion systems mobility. The diffusion layer is likely to be only a fraction of the [53]. The electrochemial oxidation of a-tocopherol in aqueous thickness of the titanate host layer (see Fig. 9: “redox process media at pH 7 occur at approximately 0.3 V vs. SCE [54]. This layer”). oxidation process is chemically highly irreversible. In addition to The (generally observed) considerable effect of the titanate film the process indicated in the reaction equation 5, also one-electron thickness on the peak currents is indicative of another more mobile oxidation followed by radical dimerisation has been reported [54]. species being involved in the process. Ion transport through the titanate film and exchange with the outside solution is required for charge neutrality to be maintained. The amount of freely mobile ions in the titanate nanosheet layer will depend on the thickness, and therefore a thicker film might simply increase the amount of available freely mobile ions to sustain the voltammetric peak signal (see Fig. 9: “ion transport layer”). This also explains the increase in When immobilised into titanate nanosheet films from 2.5 mM peak current with higher salt concentration in the outside elec- a-tocopherol solution in cyclopentanone, the irreversible oxidation trolyte as associated with increased salt partitioning. response is clearly observed (Fig. 8A). Doubling the titanate film The improved chemical stability of TPPMnCl in high concen- thickness does lead to an approximate doubling of the anodic peak tration NaCl seems very likely to be linked to suppression of chlo- current in the voltammetric response. Only the first potential cycle ride loss/ligand exchange after reduction (or suppression of is shown as the following potential cycles showed only insignificant exchange with other ligands such as phosphate). In contrast, dec- peak currents (due to chemical irreversibility). Experiments were amethylferricenium does seem to escape from the redox process performed to investigate the effect of the organic solvent on the layer consistent with literature observations for solid state reac- immobilisation process (see Fig. 8B). Each solvent clearly affects the tivity and dissolution of decamethylferricenium cations [40]. The immobilisation differently with ethanol, acetone, and dichloro- absence of a significant pH effect on the voltammetric signal for the methane giving higher current peaks. Chloroform appeared to be immobilised anthraquinone redox system could be linked to un- less suitable. Absorption a-tocopehol from cyclopentanone pro- buffered conditions inside of the titanate nanosheet film (there is vided an intermediate current response. no internal buffer system to link to the outside aqueous buffer Data in Fig. 8C show anodic peak current data (first potential system). This is confirmed by the widening peak-to-peak separa- cycle) for a-tocopherol oxidation after absorption from cyclo- tion for reduction and oxidation peaks for anthraquinone de- pentanone. The increase in peak current is close to linear and oc- rivatives upon increasing the NaCl electrolyte concentration. curs over a considerable range of concentrations. At the lower During reduction of anthraquinone, the local pH inside of the nanosheet host increases and the reduction peak shifts negative. concentration limit, voltammetric peaks are too broad to be clearly detected under these conditions. Therefore practical analytical During oxidation the pH decreases and the oxidation peak shifts applications will require further optimisation and improvement of positive. The results probably also indicate that for anthraquinone the current response. Raman spectroscopy data (Fig. 8D) show that reduction an exchange of anions occurs rather than the exchange of 10 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 Fig. 8. (A) Cyclic voltammogram (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for a-tocopherol extracted from 2.5 mM solution in cyclopentanone at (i) 1.9 mm thickness titanate film modified GCE and (ii) 3.3 mm thickness titanate film modified GCE. (B) Cyclic voltammograms (scan rate 100 mVs ; in 0.1 M phosphate buffer pH 7) for a-tocopherol extracted from 2.5 mM solution in (i) dichloromethane, (ii) ethanol, (iii) acetone, (iv) chloroform at 1.9 mm thickness titanate film modified GCE. (C) Plot of peak current versus concentration of a-tocopherol in cyclopentanone solution (estimated error 10%). (D) Raman spectra of a pure titanate film (i, blue) and a film with absorbed a-tocopherol (ii, orange). The * symbols indicates a silicon substrate signal. Fig. 9. Schematic depiction of a redox process A / AH within a thin layer in a titanate nanosheet film associated with ion transport in the ion transport layer and with ion þ þ exchange at the titanate j aqueous electrolyte interface. The aqueous electrolyte is denoted C and X . Uptake of C is suggeted to compete to exfoliation of titanate poly-anions. cations or protons (Fig. 9). Due to titanate nanosheet carrying decamethylferrocene in titanate film deposits. This also can be multiple negative charges, these may also act as poly-anions with attributed to titanate nanosheet poly-anions swelling and partially low mobility but high concentration. This could lead to competition transferring into the aqueous phase. between cation uptake at the interface titanatejaqueous electrolyte The ability to readily bind hydrophobic molecules from organic and swelling with partial poly-anion hydration. The titanate poly- solution directly into titanate nanosheet hosts seems novel and anion concentration at the interface is always (intrinsically) high potentially important for analyte extraction followed by voltam- and therefore cation uptake could be slower. The potential drift of metric detection. In this study, only relatively high concentrations voltammetric responses (e.g. observed for TPPMnCl) may occur due of analyte (in the milli-molar range) were investigated and there- to build up of interfacial charges during poly-anion swelling at the fore for analytical applications further optimisation will be required titanatejaqueous electolyte interface (see illustration in Fig. 9). The to enhance voltammetric current signals (this could be achieved for interfacial potential between titanate film and outside aqueous example by increasing ionic strength, by more careful choice of the solution phase may be poorly defined and drifting, as seen in the supporting electrolyte system, by design of the inter-lamellar data for consecutively potential cycled TPPMnCl or space, and by pulse voltammetry). More generally, this study W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 11 shows how 2D-nanosheet materials affect binding and reactivity of Acknowledgments redox active analytes and there should be a wider search for more selective and more strongly binding 2D-nanosheet materials based B.R.P. thanks to Indonesian Endowment (LPDP RI) for a PhD on other related types of systems. The role of the alkylammonium scholarship. W.T.W. acknowledges support from the Directorate of cation used during exfoliation appears to be important. The inter- Collaboration and the International Program of Bogor Agricultural play of swelling, absorption and binding, and transfer to an University for Short Term Research Program funding. analytical detection device seem to be an attribute of lamellar or 2D materials and this could be further developed for routine analytical References detection. [1] P. Wang, Z.B. Mai, Z. Dai, Y.X. Li, X.Y. Zou, Construction of Au nanoparticles on choline chloride modified glassy carbon electrode for sensitive detection of 4. Conclusions nitrite, Biosens. Bioelectron. 24 (2009) 3242e3324. [2] S.J. Guo, S.J. Dong, Graphene nanosheet: synthesis, molecular engineering, It has been demonstrated that highly lipophilic redox active thin film, hybrids, and energy and analytical applications, Chem. Soc. Rev. 40 species such as anthraquinone, 1-aminoanthraquinone, deca- (2011) 2644e2672. [3] A. Sinha, Dhanjai, H.M. Zhao, Y.J. Huang, X.B. Lu, J.P. Chen, R. Jain, MXene: an methylferrocene, TPPMnCl, and a-tocopherol are readily immobi- emerging material for sensing and biosensing, Trac. Trends Anal. Chem. 105 lised into titanate nanosheet film deposits at glassy carbon (2018) 424e435. electrode surfaces. These redox species bind from organic solvents, [4] A. Sinha, Dhanjai, B. Tan, Y.J. Huang, H.M. Zhao, X.M. Dang, J.P. Chen, R. Jain, MoS nanostructures for electrochemical sensing of multidisciplinary targets: in particular from cyclopentanone. The effect of the organic solvent a review, Trac. Trends Anal. Chem. 102 (2018) 75e90. on the swelling/absorption process suggests some involvement of [5] M. Pumera, A.H. Loo, Layered transition-metal dichalcogenides (MoS and the solvent by co-intercalation. WS ) for sensing and biosensing, Trac. Trends Anal. Chem. 61 (2014) 49e53. [6] B.Q. Yuan, C.Y. Xu, D.H. Deng, Y. Xing, L. Liu, H. Pang, D.J. Zhang, Graphene Electrochemical processes for titanate nanosheet immobilised oxide/nickel oxide modified glassy carbon electrode for supercapacitor and species are similar to those reported for organic microphase envi- nonenzymatic glucose sensor, Electrochim. Acta 88 (2013) 708e712. ronments and associated with electron transfer driven processes [7] F.W. Li, D.R. MacFarlane, J. Zhang, Recent advances in the nanoengineering of electrocatalysts for CO reduction, Nanoscale 10 (2018) 6235e6260. coupled to interfacial ion exchange. As a result, usually pH-sensitive 2 [8] S. Bai, Y.J. Xiong, Recent advances in two-dimensional nanostructures for processes, for example for anthraquinone reduction and for a- catalysis applications, Sci. Adv. Mater. 7 (2015) 2168e2181. tocopherol oxidation, become pH-insensitive and associated with [9] G.H. Yang, C.Z. Zhu, D. Du, J.J. Zhu, Y.H. Lin, Graphene-like two-dimensional layered nanomaterials: applications in biosensors and nanomedicine, Nano- exchange of other types of electrolyte ions. Diffusion of redox active scale 7 (2015) 14217e14231. species such as anthraquinone and 1-aminoanthraquinone appears [10] M.J. Wang, Z. Fan, L.Q. Yi, J.S. Xu, X.B. Zhang, Z.W. Tong, Construction of iron to be possible within the titanate nanosheets, but is suggested to be porphyrin/titanoniobate nanosheet sensors for the sensitive detection of ni- trite, J. Mater. Sci. 53 (2018) 11403e11414. slow and contained within a thin zone close to the electrode sur- [11] W.T. Wahyuni, B.R. Putra, C. Harito, D.V. Bavykin, F.C. Walsh, T.D. James, face. Diffusion of excess electrolyte within the inter-lamellar space G. Kociok-Kohn, € F. Marken, Electroanalysis in 2D-TiO nanosheet hosts: appears to be linked to the process responsible for voltammetric electrolyte and selectivity effects in ferroceneboronic acid - saccharide bind- characteristics. Redox processes for other types of species such as ing, Electroanalysis 30 (2018) 1303e1310. [12] D.V. Bavykin, F.C. Walsh, Titanate and Titania Nanotubes: Synthesis, Proper- decamethylferrocene and TPPMnCl show gradual loss of peak cur- ties and Applications, Royal Society of Chemistry Nanoscience and Nano- rents, presumably due to either loss of redox active material away technology Monograph, London, 2009. ISBN: 978-1-84755-910-4. from the reaction zone or loss due to chemical instability (loss of [13] D.V. Bavykin, J.M. Friedrich, F.C. Walsh, Protonated titanates and TiO nano- structured materials: synthesis, properties and applications, Adv. Mater. 18 chloride from the Mn(II) complex) based on the conditions within (2006) 2807e2824. the titanate nanosheet film. a-Tocopherol is oxidised in a chemi- [14] D.V. Bavykin, F.C. Walsh, The kinetics of alkali metal ion-exchange into cally irreversible manner, but shows a close to linear plot of anodic nanotubular and nanofibrous titanates, J. Phys. Chem. C 111 (2007) 14644e14651. peak current versus concentration in a 1 mMe20 mM concentration [15] T. Sasaki, M. Watanabe, Semiconductor nanosheet crystallites of quasi-TiO range. Therefore probing of a-tocopherol concentration in organic and their optical properties, J. Phys. Chem. B 101 (1997) 10159e10161. oil media could be performed directly by binding into titanate [16] T. Sasaki, Y. Ebina, Y. Kitami, M. Watanabe, T. Oikawa, Two-dimensional diffraction of molecular nanosheet crystallites of titanium oxide, J. Phys. nanosheet film electrodes. However, for analytical application the Chem. B 105 (2001) 6116e6121. sensitivity needs to be improved substantially. The mechanism for [17] N. Sakai, Y. Ebina, K. Takada, T. Sasaki, Electronic band structure of titania electron transfer within the lamellar host also needs further study. semiconductor nanosheets revealed by electrochemical and photo- Finally, the binding and mobility of guest species in the lamellar electrochemical studies, J. Am. Chem. Soc. 126 (2004) 5851e5858. [18] T. Sasaki, Molecular nanosheets of quasi-TiO : preparation and spontaneous host deserves further investigation. reassembling, Supramol. Sci. 5 (1998) 367e371. In the future, titanate nanosheet film deposits could be [19] T. Sasaki, M. Watanabe, H. Hashizume, H. Yamada, H. Nakazawa, Macromol- employed in separation and analytical detection based on extrac- ecule-like aspects for a colloidal suspension of an exfoliated titanate. Pairwise association of nanosheets and dynamic reassembling process initiated from it, tion from organic solvent media. For this, for example the exfolia- J. Am. Chem. Soc. 118 (1996) 8329e8335. tion cation could be modified to provide additional analyte [20] C. Harito, D.V. Bavykin, M.E. Light, F.C. Walsh, Titanate nanotubes and nano- selectivity and binding. Particularly useful could be the ability to sheets as a mechanical reinforcement of water-soluble polyamic acid: experimental and theoretical studies, Composites Part B 124 (2017) 54e63. respond to different types of solvents and to bind guests from a [21] A.S. Martins, C. Harito, D.V. Bavykin, F.C. Walsh, M.R.V. Lanza, Insertion of range of solvents ranging from highly polar to highly non-polar. nanostructured titanates into the pores of an anodized TiO nanotubes array Sensors based on a titanate film electrolyte may in future be able by mechanically stimulated electrophoretic deposition, J. Mater. Chem. C 5 (2017) 3955e3961. to operate in organic sample media based on natural oils, edible [22] H.B. Huang, Y.L. Ying, X.S. Peng, Graphene oxide nanosheet: an emerging star oils, industry oil samples, or in the gas phase. Colour evidence and material for novel separation membranes, J. Mater. Chem. 2 (2014) Raman spectroscopy evidence for binding as well as electro- 13772e13782. [23] F. Marken, J.D. Watkins, A.M. Collins, Ion-transfer- and photo- chemical detection have been demonstrated. Therefore both elec- electrochemistry at liquid j liquid j solid electrode triple phase boundary trochemical and non-electrochemical modes of detection in junctions: perspectives, Phys. Chem. Chem. Phys. 13 (2011) 10036e10047. titanates may also be possible. [24] T. Sasaki, M. Watanabe, Osmotic swelling to exfoliation. Exceptionally high degrees of hydration of a layered titanate, J. Am. Chem. Soc. 120 (1998) 4682e4689. Declaration of interest [25] L.Z. Wang, T. Sasaki, Titanium oxide nanosheets: graphene analogues with versatile functionalities, Chem. Rev. 114 (2014) 9455e9486. There are no competing interests to declare by the authors. [26] G. Matricali, M.M. Dieng, J.F. Dufeu, M. Guillou, Electrochemistry in solid-state 12 W.T. Wahyuni et al. / Analytica Chimica Acta: X 1 (2019) 100001 of 9,10-anthraquinone-anthraquinol couple e use in negative electrode- [43] Y.Y. Rong, R. Malpass-Evans, M. Carta, N.B. McKeown, G.A. Attard, F. Marken, reactions of secondary electrochemical generators, Electrochim. Acta 21 High density heterogenisation of molecular electrocatalysts in a rigid intrin- (1976) 943e952. sically microporous polymer, Electrochem. Commun. 46 (2014) 26e29. [27] A. Ullah, A. Rauf, U.A. Rana, R. Qureshi, M.N. Ashiq, H. Hussain, H.B. Kraatz, [44] M.J. Bonne, C. Reynolds, S. Yates, G. Shul, J. Niedziolka, M. Opallo, F. Marken, A. Badshah, A. Shah, pH dependent electrochemistry of anthracenediones at a The electrochemical ion-transfer reactivity of porphyrinato metal complexes glassy carbon electrode, J. Electrochem. Soc. 162 (2015) H157eH163. in 4-(3-phenylpropyl)pyridine vertical bar water systems, New J. Chem. 30 [28] L. Devlin, M. Jamal, K.M. Razeeb, Novel pH sensor based on anthraquinone- (2006) 327e334. ferrocene modified free standing gold nanowire array electrode, Anal. [45] G.J. Foran, R.S. Armstrong, M.J. Crossley, P.A. Lay, Effect of electrolytes con- Methods 5 (2013) 880e884. centration on axial anion ligation in manganese(III) meso- [29] F. Scholz, Electroanalytical Methods, Springer, Berlin, 2010, p. 69. tetraphenylporphyrin chlorides, Inorg. Chem. 31 (1992) 1463e1470. [30] M.A. Ghanem, I. Kocak, A. Al-Mayouf, M. AlHoshan, P.N. Bartlett, Covalent [46] R.R. Gaughan, D.F. Shriver, L.J. Boucher, Resonance Raman-spectroscopy of modification of carbon nanotubes with anthraquinone by electrochemical manganese(III) tetraphenylporphyrin halides, Proc. Natl. Acad. Sci. Unit. States grafting and solid phase synthesis, Electrochim. Acta 68 (2012) 74e80. Am. 72 (1975) 433e436. [31] J.D. Watkins, K. Lawrence, J.E. Taylor, T.D. James, S.D. Bull, F. Marken, Carbon [47] S.C. Jeoung, D. Kim, D.W. Cho, Transient resonance Raman spectroscopic nanoparticle surface electrochemistry: high-density covalent immobilisation studies of some paramagnetic metalloporphyrins: effects of axial ligand on and pore-reactivity of 9,10-anthraquinone, Electroanalysis 23 (2011) charge-transfer and photoreduction processes, J. Raman Spectrosc. 31 (2000) 1320e1324. 319e330. [32] G.G. Wildgoose, M. Pandurangappa, N.S. Lawrence, L. Jiang, T.G.J. Jones, [48] S.N. Robledo, V.G.L. Zachetti, M.A. Zon, H. Fernandez, Quantitative determi- R.G. Compton, Anthraquinone-derivatised carbon powder: reagentless vol- nation of tocopherols in edible vegetable oils using electrochemical ultra- tammetric pH electrodes, Talanta 60 (2003) 887e893. microsensors combined with chemometric tools, Talanta 116 (2013) [33] E.V. Milsom, J. Novak, S.J. Green, X.H. Zhang, S.J. Stott, R.J. Mortimer, K. Edler, 964e971. F. Marken, Layer-by-layer deposition of open-pore mesoporous TiO -Nafion [49] M. Sys, B. Svecova, I. Svancara, R. Metelka, Determination of vitamin E in (R) film electrodes, J. Solid State Electrochem. 11 (2007) 1109e1117. margarines and edible oils using square wave anodic stripping voltammetry [34] T. Gao, H. Fjellvag, P. Norby, Raman scattering properties of a protonic titanate with a glassy carbon paste electrode, Food Chem. 229 (2017) 621e627. H Ti , H O(x ¼ 0.7) with lepidocrocite-type layered structure, [50] T. Kondo, K. Sakai, T. Watanabe, Y. Einaga, M. Yuasa, Electrochemical detection x 2-x/4 O-x/4 2 J. Phys. Chem. B 112 (2008) 9400e9405. of lipophilic antioxidants with high sensitivity at boron-doped diamond [35] T. Gao, H. Fjellvag, P. Norby, Protonic titanate derived from Cs Ti Mg O electrode, Electrochim. Acta 95 (2013) 205e211. x 2-x/2 x/2 4 (x ¼ 0.7) with lepidocrocite- type layered structure, J. Mater. Chem. 19 (2009) [51] M. Coatanea, A. Darchen, D. Hauchard, Electroanalysis at ultramicroelectrodes 787e794. of oils and fats - application to the determination of Vitamin E, Sens. Actuators [36] K.K. Lehmann, J. Smolarek, O.S. Khalil, L. Goodman, Vibrational assignments B-Chem. 76 (2001) 539e544. for the Raman and phosphorescence spectra of 9,10-anthraquinone and 9,10- [52] W.W. Yao, H.M. Peng, R.D. Webster, Electrochemistry of a-tocopherol (vitamin anthraquinone-d , J. Phys. Chem. 83 (1979) 1200e1205. E) and a-tocopherol quinone films deposited on electrode surfaces in the [37] F. Stenman, Raman scattering from powdered 9,10-anthraquinone, J. Chem. presence and absence of lipid multilayers, J. Phys. Chem. C 113 (2009) Phys. 51 (1969) 3413e3415. 21805e21814. [38] K. Peckova, H. FiizAyyidjz, M. Topkafa, H. Kara, M. Ersoz, J. Barek, Polaro- [53] M.A. Ghanem, R.G. Compton, B.A. Coles, A. Canals, F. Marken, Microwave graphic and voltammetric determination of trace amounts of 2- enhanced electroanalysis of formulations: processes in micellar media at aminoanthraquinone, Chem. Anal. 52 (2007) 989e1001. glassy carbon and at platinum electrodes, Analyst 130 (2005) 1425e1431. [39] V. Kratochvil, M. Nepras, Anthraquinone dystuffs.14. Protonation of 9,10- [54] A.J. Wain, J.D. Wadhawan, R.R. France, R.G. Compton, Biphasic redox chem- anthraquinone derivatives, Collect. Czech Chem. Commun. 37 (1972) istry of a-tocopherol: evidence for electrochemically induced hydrolysis and 1533e1535. dimerization on the surface of and within femtolitre droplets immobilized [40] A.M. Bond, F. Marken, Mechanistic aspects of the electro and ion-transport onto graphite electrodes, Phys. Chem. Chem. Phys. 6 (2004) 836e842. processes across the electrode solid solvent (electrolytes) interface of micro- [55] J.R. Beattie, C. Maguire, S. Gilchrist, L.J. Barrett, C.E. Cross, F. Possmayer, crystalline decamethylferrocene attached mechanically to a graphite elec- M. Ennis, J.S. Elborn, W.J. Curry, J.J. McGarvey, B.C. Schock, The use of Raman trode, J. Electroanal. Chem. 372 (1994) 125e135. microscopy to determine and localize vitamin E in biological samples, Faseb. J. [41] G.F. Manbeck, E. Fujita, A review of iron and cobalt porphyrins, phthalocya- 21 (2007) 766e776. nines and related complexes for electrochemical and photochemical reduc- [56] C.E. Banks, T.J. Davies, R.G. Evans, G. Hignett, A.J. Wain, N.S. Lawrence, tion of carbon dioxide, J. Porphyr. Phthalocyanines 19 (2015) 45e64. J.D. Wadhawan, F. Marken, R.G. Compton, Microdroplet review Electro- [42] C. Costentin, M. Robert, J.M. Saveant, Molecular catalysis of electrochemical chemistry of immobilised redox droplets: concepts and applications, Phys. reactions, Curr. Opinion Electrochem. 2 (2017) 26e31. Chem. Chem. Phys. 5 (2003) 4053e4069.
Analytica Chimica Acta X – arXiv (Cornell University)
Published: Apr 2, 2020
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.