Cold Zone Exploration Using Position of Maximum Nusselt Number for Inclined Air Jet Cooling

Cold Zone Exploration Using Position of Maximum Nusselt Number for Inclined Air Jet Cooling AbstractInclined jet air cooling can be effectively used for cooling of electronics or other such applications. The non-confined air jet is impinged and experimentally investigated on the hot target surface to be cooled, which is placed horizontally. Analysis and evaluations are made by introduction of a jet on the leading edge and investigated for downhill side cooling to identify cold spots. The jet Reynolds number in the range of 2000 ≤ Re ≤ 20 000 is examined with a circular jet for inclination (Θ) of 15 < Θ < 75 degree. Also, the consequence of a jet to target distance (H) is explored in the range 0:5 ≤ H/D ≤ 6.8. For 45 degree jet impingement, the maximum Nusselt number is widely spread. Location of maximum Nusselt number is studied, which indicates cold spots identification. At a higher angle ratio, the angle is the dominating parameter compared to the Reynolds Number. Whereas at a lower angle ratio, the inclined jet with a higher Reynolds number is giving the cooling point away from leading edge. It is observed that for a particular angle of incident location of maximum Nusselt Number, measured from leading edge of target, is ahead than that of stagnation point in stated conditions. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archive of Mechanical Engineering de Gruyter

Cold Zone Exploration Using Position of Maximum Nusselt Number for Inclined Air Jet Cooling

Loading next page...
 
/lp/de-gruyter/cold-zone-exploration-using-position-of-maximum-nusselt-number-for-qpJQEuMvOw

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
de Gruyter
Copyright
© by Sunil B. Ingole
ISSN
2300-1895
eISSN
2300-1895
DOI
10.1515/meceng-2017-0031
Publisher site
See Article on Publisher Site

Abstract

AbstractInclined jet air cooling can be effectively used for cooling of electronics or other such applications. The non-confined air jet is impinged and experimentally investigated on the hot target surface to be cooled, which is placed horizontally. Analysis and evaluations are made by introduction of a jet on the leading edge and investigated for downhill side cooling to identify cold spots. The jet Reynolds number in the range of 2000 ≤ Re ≤ 20 000 is examined with a circular jet for inclination (Θ) of 15 < Θ < 75 degree. Also, the consequence of a jet to target distance (H) is explored in the range 0:5 ≤ H/D ≤ 6.8. For 45 degree jet impingement, the maximum Nusselt number is widely spread. Location of maximum Nusselt number is studied, which indicates cold spots identification. At a higher angle ratio, the angle is the dominating parameter compared to the Reynolds Number. Whereas at a lower angle ratio, the inclined jet with a higher Reynolds number is giving the cooling point away from leading edge. It is observed that for a particular angle of incident location of maximum Nusselt Number, measured from leading edge of target, is ahead than that of stagnation point in stated conditions.

Journal

Archive of Mechanical Engineeringde Gruyter

Published: Dec 20, 2017