Access the full text.
Sign up today, get DeepDyve free for 14 days.
A. Patil, Xiao-an Fu, M. Mehregany, S. Garverick (2009)
Fully-monolithic, 600°C differential amplifiers in 6H-SiC JFET IC technology2009 IEEE Custom Integrated Circuits Conference
Ninoska Ramírez, M. Fortes, A. Salgado, Belkis Valdman (2009)
Construcción de un Inmunosensor Amperométrico utilizando Apirasa de Solanum tuberosum para la Detección de Esquistosomiasis, 20
J. Colomer-Farrarons, P. Miribel-Català, I. Rodríguez, J. Samitier (2009)
CMOS front-end architecture for In-Vivo biomedical implantable devices2009 35th Annual Conference of IEEE Industrial Electronics
J. Colomer-Farrarons, P. Miribel-Català (2011)
Energy Harvesting (Multi Harvesting Power Chip)
A. Veeravalli, E. Sánchez-Sinencio, J. Silva-Martínez (2002)
Transconductance amplifier structures with very small transconductances: a comparative design approachIEEE J. Solid State Circuits, 37
E. Lorenzo, F. Pariente, L. Hernández, F. Tobalina, M. Darder, Q. Wu, M. Maskus, H. Abruña (1998)
Analytical strategies for amperometric biosensors based on chemically modified electrodes.Biosensors & bioelectronics, 13 3-4
Christine Berggren, B. Bjarnason, Gillis Johansson (1998)
An immunological interleukine-6 capacitive biosensor using perturbation with a potentiostatic step.Biosensors & bioelectronics, 13 10
S. Kailasa, S. Kang (2009)
Microchip‐Based Capillary Electrophoresis for DNA Analysis in Modern Biotechnology: A ReviewSeparation & Purification Reviews, 38
A. Gore, S. Chakrabartty, Sudeshna Pal, E. Alocilja (2006)
A Multichannel Femtoampere-Sensitivity Potentiostat Array for Biosensing ApplicationsIEEE Transactions on Circuits and Systems I: Regular Papers, 53
F. Serra-Graells, J. Huertas (2003)
Low-Voltage CMOS Log Companding Analog Design
K. Kasem, Stephanie Jones (2008)
Platinum as a Reference Electrode in Electrochemical MeasurementsPlatinum Metals Review, 52
R. Northrop (2004)
Analysis and Application of Analog Electronic Circuits to Biomedical Instrumentation (Biomedical Engineering)
Weize Xu, E. Friedman (2004)
Clock Feedthrough in Cmos Analog Transmission Gate Switches *
J. Webster (1997)
Medical Instrumentation: Application and Design
J. Close, F. Santos (1993)
A JFET input single supply operational amplifier with rail-to-rail output1993 Proceedings of IEEE Bipolar/BiCMOS Circuits and Technology Meeting
E. Katz, I. Willner (2003)
Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme BiosensorsElectroanalysis, 15
Z. Tang, Brian Smith, J. Schild, P. Peckham (1995)
Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulatorIEEE Transactions on Biomedical Engineering, 42
F. Heer, W. Franks, A. Blau, S. Taschini, C. Ziegler, A. Hierlemann, H. Baltes (2004)
CMOS microelectrode array for the monitoring of electrogenic cells.Biosensors & bioelectronics, 20 2
V. Ivama, S. Serrano (2003)
Rhodium-Prussian Blue modified carbon paste electrode (Rh-PBMCPE) for amperometric detection of hydrogen peroxideJournal of the Brazilian Chemical Society, 14
P. Bartlett, R. Whitaker (1987)
Strategies for the development of amperometric enzyme electrodes.Biosensors, 3 6
D. Rairigh, A. Mason, Chao Yang (2006)
Analysis of On-Chip Impedance Spectroscopy Methodologies for Sensor ArraysSensor Letters, 4
W. Lin, S. Pillay (1974)
A micropower pulsewidth-modulation-pulse-position-modulation two-channel telemetry system for biomedical applications.IEEE transactions on bio-medical engineering, 21 4
S. Haddad, W. Serdijn (2009)
Ultra Low-Power Biomedical Signal Processing: An Analog Wavelet Filter Approach for Pacemakers
S. Hasan (2007)
Stability Analysis and Novel Compensation of a CMOS Current-Feedback Potentiostat Circuit for Electrochemical SensorsIEEE Sensors Journal, 7
A.E. Moe, Steve Marx, Iqbal Bhinderwala, Denise Wilson (2004)
A miniaturized lock-in amplifier design suitable for impedance measurements in cells [biological cells]Proceedings of IEEE Sensors, 2004.
J. Webster (1988)
Encyclopedia of Medical Devices and Instrumentation
A. Bard, L. Faulkner (1980)
Electrochemical Methods: Fundamentals and Applications
Xue-ping Gan, Yating Wu, Lei Liu, Wenbin Hu (2007)
Effects of K4Fe(CN)6 on electroless copper plating using hypophosphite as reducing agentJournal of Applied Electrochemistry, 37
Liju Yang, Yanbin Li, C. Griffis, Michael Johnson (2004)
Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium.Biosensors & bioelectronics, 19 10
Wen-Yaw Chung, A. Paglinawan, Ying-Hsiang Wang, T. Kuo (2007)
A 600 μW readout circuit with potentiostat for amperometric chemical sensors and glucose meter applications2007 IEEE Conference on Electron Devices and Solid-State Circuits
L. Adams, R. Mackay (1969)
Bio-Medical TelemetryBioScience
R. Gregorian (1999)
Introduction to CMOS OP-AMPs and Comparators
I. Bontidean, Christine Berggren, Gillis Johansson, E. Csöregi, Bo Mattiasson, Jon Lloyd, K. Jakeman, Nigel Brown (1998)
Detection of heavy metal ions at femtomolar levels using protein-based biosensors.Analytical chemistry, 70 19
D. Nd (1986)
Passive signalling via inductive coupling.Medical & Biological Engineering & Computing, 24
R. Hogervorst, J. Tero, R.G.H. Eschauzier, J. Huijsing (1994)
A compact power-efficient 3 V CMOS rail-to-rail input/output operational amplifier for VLSI cell librariesProceedings of IEEE International Solid-State Circuits Conference - ISSCC '94
L. Woo, L. Martin, R. Glass, R. Gorte (2006)
Impedance Characterization of a Model Au ∕ Yttria -Stabilized Zirconia ∕ Au Electrochemical Cell in Varying Oxygen and NO x ConcentrationsJournal of The Electrochemical Society, 154
D. McCulloch, G. Boemel, M. Borchert (1997)
Comparisons of contact lens, foil, fiber and skin electrodes for patterns electroretinogramsDocumenta Ophthalmologica, 94
A. Arnaud, R. Fiorelli, C. Galup-Montoro (2006)
Nanowatt, Sub-nS OTAs, With Sub-10-mV Input Offset, Using Series-Parallel Current MirrorsIEEE Journal of Solid-State Circuits, 41
Xiaobo Ji, C. Banks, A. Crossley, R. Compton (2006)
Oxygenated edge plane sites slow the electron transfer of the ferro-/ferricyanide redox couple at graphite electrodes.Chemphyschem : a European journal of chemical physics and physical chemistry, 7 6
S. Martin, F. Gebara, B. Larivee, Richard Brown (2005)
A CMOS-integrated microinstrument for trace detection of heavy metalsIEEE Journal of Solid-State Circuits, 40
A. Gore, S. Chakrabartty, Sudeshna Pal, E. Alocilja (2006)
A multi-channel femtoampere-sensitivity conductometric array for biosensing applications2006 International Conference of the IEEE Engineering in Medicine and Biology Society, Supplement
C. Dumschat, H. Müller, K. Stein, G. Schwedt (1991)
Pesticide-sensitive ISFET based on enzyme inhibitionAnalytica Chimica Acta, 252
P. Bergveld (2003)
Thirty years of ISFETOLOGY ☆: What happened in the past 30 years and what may happen in the next 30 yearsSensors and Actuators B-chemical, 88
S. Radke, E. Alocilja (2005)
A microfabricated biosensor for detecting foodborne bioterrorism agentsIEEE Sensors Journal, 5
H. Ferreira, D. Daniel, M. Bertotti, E. Richter (2008)
A novel disposable electrochemical microcell: construction and characterizationJournal of the Brazilian Chemical Society, 19
F. Mizutani, T. Yamanaka, Y. Tanabe, K. Tsuda (1985)
An enzyme electrode forl-lactate with a chemically-amplified responseAnalytica Chimica Acta, 177
J. Huijsing (2000)
Operational Amplifiers - Theory and Design
F. Maloberti (2001)
Analog Design for CMOS VLSI Systems
B. Conway (1974)
Modern Aspects of Electrochemistry
F. Padmadinata, J. Veerhoek, G. Dijk, J. Huijsing (1990)
Microelectronic skin electrodeSensors and Actuators B-chemical, 1
B. Lenaerts, R. Puers (2008)
Omnidirectional Inductive Powering for Biomedical Implants
E. Lauwers, J. Suls, W. Gumbrecht, D. Maes, G. Gielen, W. Sansen (2001)
A CMOS multi-parameter biochemical microsensor with temperature control and signal interfacing2001 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC (Cat. No.01CH37177)
L. Morrison (1988)
Time-resolved detection of energy transfer: theory and application to immunoassays.Analytical biochemistry, 174 1
A. Marcellis, G. Ferri, M. Patrizi, V. Stornelli, A. D'Amico, C. Natale', E. Martinelli, A. Alimelli, R. Paolesse (2007)
An integrated analog lock-in amplifier for low-voltage low-frequency sensor interface2007 2nd International Workshop on Advances in Sensors and Interface
D. Cullen, R. Sethi, C. Lowe (1990)
Multi-analyte miniature conductance biosensorAnalytica Chimica Acta, 231
R. Reay, S. Kounaves, Gregory Kovacs (1994)
An integrated CMOS potentiostat for miniaturized electroanalytical instrumentationProceedings of IEEE International Solid-State Circuits Conference - ISSCC '94
[This Chapter is focused on the development of an integrated instrumentation to work with three electrodes amperometric Biosensor. First of all, it is introduced the conception of three electrodes configuration and how it works. Moreover, some typical electrochemical techniques like Voltammetry, EIS and amperometry, are introduced to the reader. The instrumentation electronics is based on a potentiostat architecture, which is explained in detail and experimentally validated. The obtained results with the full-custom approach are compared with the ones obtained using a commercial potentiostat. In that way, the correct operation of the designed circuits is fully validated. Furthermore, this chapter explains the conception of a Lock-In amplifier circuit used to detect the real and imaginary components of the complex impedance measured from the Biosensor. This circuit is theoretically explained and some simulated results are shown. Finally, the conception of Biotelemetry or how to transmit information from the subcutaneous device to the external reader is introduced. Then, the implemented protocol in this work is detailed. In summary, this chapter presents the developed BioChip IC that is able to drive the sensor, process the measured data and transmit the data to the external side through an inductive link.]
Published: Jan 20, 2011
Keywords: Analog integrated circuits; Microelectronic implants; Bioimpedance; Amperometric sensors; Electrochemical impedance spectroscopy; Phase detection; Active filters; Biomedical telemetry
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.