Analysis of parametric optimization on the design of negative pressure room Negative pressure rooms are crucial for the prevention of the dispersion of infectious diseases. Using the ANSYS-Fluent finite volume method (FVM), standard k ϵ turbulent, species transport, and discrete phase model with the transient condition, this research aims to reduce the amount of airborne contamination inside the negative pressure room. In the current design, both 10 area ratios and static supply pressures 1 – 30 Pa are considered. The optimum condition is reached at an area ratio of 9 and 13 Air change per hours (ACHs) with a 96% reduction in CO2 concentration and an exhaust velocity of 3 m/s and a minimum power consumption of 247 W at a supply pressure of ( 10) Pa. The effective direct airflow pattern is observed as a safe environment by analyzing the streamlines and velocity vector distributions. To prevent the infectious viruses spread, the particle tracking of coughed droplets is analyzed so that 100% of aerosol particles can be extracted within 3 s. The door-opening effect showed that the desired negative pressure could be maintained even if the door opened for a long time. This work will benefit the design engineers for any intended negative pressure room and provide a secure working environment for the medical personnel. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Advances in Building Energy Research Taylor & Francis

Analysis of parametric optimization on the design of negative pressure room

28 pages

Loading next page...
 
/lp/taylor-francis/analysis-of-parametric-optimization-on-the-design-of-negative-pressure-pBkvAzKQDk

References (57)

Publisher
Taylor & Francis
Copyright
© 2023 Informa UK Limited, trading as Taylor & Francis Group
ISSN
1756-2201
eISSN
1751-2549
DOI
10.1080/17512549.2023.2215789
Publisher site
See Article on Publisher Site

Abstract

Negative pressure rooms are crucial for the prevention of the dispersion of infectious diseases. Using the ANSYS-Fluent finite volume method (FVM), standard k ϵ turbulent, species transport, and discrete phase model with the transient condition, this research aims to reduce the amount of airborne contamination inside the negative pressure room. In the current design, both 10 area ratios and static supply pressures 1 – 30 Pa are considered. The optimum condition is reached at an area ratio of 9 and 13 Air change per hours (ACHs) with a 96% reduction in CO2 concentration and an exhaust velocity of 3 m/s and a minimum power consumption of 247 W at a supply pressure of ( 10) Pa. The effective direct airflow pattern is observed as a safe environment by analyzing the streamlines and velocity vector distributions. To prevent the infectious viruses spread, the particle tracking of coughed droplets is analyzed so that 100% of aerosol particles can be extracted within 3 s. The door-opening effect showed that the desired negative pressure could be maintained even if the door opened for a long time. This work will benefit the design engineers for any intended negative pressure room and provide a secure working environment for the medical personnel.

Journal

Advances in Building Energy ResearchTaylor & Francis

Published: Jul 4, 2023

Keywords: Negative pressure room; finite volume method (FVM); area ratios; droplets particles tracking; minimum power consumption

There are no references for this article.