Access the full text.
Sign up today, get DeepDyve free for 14 days.
J. Singley, Ting-Ye Lee (1984)
Pipe loop system augments corrosion studiesJournal American Water Works Association, 76
(1994)
The importance of stringent control of DIC and pH in laboratory corrosion studies: Theory and practice
(2015)
Pipe loop studies of orthophosphate addition for control of lead release in high pH, low DIC waters
(2018)
City of Newark Lead and copper rule compliance study (document 67-1)
Damon Roth, J. Wagner, D. Cornwell (2018)
Impacts of Source Water Blending on Lead ReleaseJournal ‐ American Water Works Association, 110
(1995)
Pipe loop testing at the lowell water treatement plant
M. Woszczynski, J. Bergese, G. Gagnon (2013)
Comparison of Chlorine and Chloramines on Lead Release from Copper Pipe RigsJournal of Environmental Engineering, 139
(2009)
Lead leaching from lead service lines: Impact of disinfection type, stagnation time, and scale chemistry
D. Churchill, D. Mavinic, D. Neden, D. Macquarrie (2000)
The effect of zinc orthophosphate and pH- alkalinity adjustment on metal levels leached into drinking waterCanadian Journal of Civil Engineering, 27
G. Treweek, Joe Glicker, Bruce Chow, M. Sprinker (1985)
Pilot‐plant Simulation of Corrosion in Domestic Pipe MaterialsJournal American Water Works Association, 77
S. Harmon, Jennifer Tully, Michael DeSantis, M. Schock, Simoni Triantafyllidou, D. Lytle (2022)
A holistic approach to lead pipe scale analysis: Importance, methodology, and limitationsAWWA Water Science, 4
Yan Zhang, Tai Tseng, Cynthia Andrews-Tate, R. Cheng, Kevin Wattier (2012)
Pilot‐scale evaluation of blending desalinated seawater into a distribution systemJournal ‐ American Water Works Association, 104
(2021)
Portland's corrosion control coupon study: Lead reduction benefits of filtration for a historically unfiltered supply
Barbara Wysock, A. Sandvig, M. Schock, C. Frebis, B. Prokop (1995)
Statistical procedures for corrosion studiesJournal American Water Works Association, 87
Y. Bae, J. Pasteris, D. Giammar (2020)
Impact of orthophosphate on lead release from pipe scale in high pH, low alkalinity water.Water research, 177
M. Woszczynski, J. Bergese, S. Payne, G. Gagnon (2015)
Comparison of sodium silicate and phosphate for controlling lead release from copper pipe rigsCanadian Journal of Civil Engineering, 42
Clément Cartier, R. Arnold, Simoni Triantafyllidou, M. Prévost, M. Edwards (2012)
Effect of flow rate and lead/copper pipe sequence on lead release from service lines.Water research, 46 13
Taylor Bradley (2018)
Evaluation of Zinc Orthophosphate to Control Lead Solder Corrosion in Waters With High Chloride to Sulfate Mass Ratio
(2013)
Applications of a novel corrosion control treatment from bench top to full scale pilot study: The use of magnesium sulfate to mitigate lead leaching
(2020)
What we learned from pilot studies on harvested Lead service line and coupon studies under similar conditions [webinar]. An experiment in environmental leadership: Denver water variance experience
B. Trueman, G. Gagnon (2016)
Understanding the Role of Particulate Iron in Lead Release to Drinking Water.Environmental science & technology, 50 17
G. Hatch (1941)
Inhibition of Lead Corrosion with Sodium Hexametaphosphate.Journal American Water Works Association, 33
E. Moore, F. Smith (1942)
Effect of Sodium Hexametaphosphate on the Solution of LeadJournal American Water Works Association, 34
(2004)
Corrosion control optimization using lead pipe loops. Paper presented at the AWWA water quality technology conference
J. Arnold (2011)
NEW INSIGHTS INTO LEAD AND COPPER CORROSION: IMPACTS OF GALVANIC CORROSION, FLOW PATTERN, POTENTIAL REVERSAL, AND NATURAL ORGANIC MATTER
N. Lin, A. Torrents, Allen Davis, Mazyar Zeinali, F. Taylor (1997)
Lead corrosion control from lead, copper‐lead solder, and brass coupons in drinking water employing free and combined chlorineJournal of Environmental Science and Health Part A-toxic\/hazardous Substances & Environmental Engineering, 32
K. Pieper, L. Krometis, M. Edwards (2016)
Quantifying Lead‐Leaching Potential From Plumbing Exposed to Aggressive WatersJournal ‐ American Water Works Association, 108
Daniel Williams, C. Parrett, M. Schock, Christy Muhlen, Peg Donnelly, D. Lytle (2018)
Design and Testing of USEPA'S Flint Pipe Rig for Corrosion Control EvaluationJournal ‐ American Water Works Association, 110
Michael Schock, M. Gardels (1983)
Plumbosolvency reduction by high pH and low carbonate- solubility relationshipsJournal American Water Works Association, 75
Simoni Triantafyllidou, M. Raetz, Jeffrey Parks, M. Edwards (2012)
Understanding how brass ball valves passing certification testing can cause elevated lead in water when installed.Water research, 46 10
Yin Wang, H. Jing, Vrajesh Mehta, G. Welter, D. Giammar (2012)
Impact of galvanic corrosion on lead release from aged lead service lines.Water research, 46 16
(2014)
Non-intrusive methodology for assessing lead and copper corrosion
(1978)
Methods of evaluationg corrosion. American Water Works Association Water Quality Technology Conference
S. Masters, Nicole Poncelet‐Johnson, Ryan Walsh, C. Seidel, Christopher Corwin (2022)
Comparison of coupon and pipe rack studies for selecting corrosion control treatmentAWWA Water Science, 4
Simoni Triantafyllidou, M. Edwards (2011)
Galvanic corrosion after simulated small‐scale partial lead service line replacementsJournal ‐ American Water Works Association, 103
(2019)
Lead and copper corrosion bench-scale testing guidance manual
D. Cornwell, J. Wagner (2019)
Coupon Procedures for Evaluating Lead and Copper SolubilityJournal AWWA
(2009)
A pilot scale examination of lead release in simulated premise plumbing systems. Dalhousie University. eCFR (electronic Code of Federal Regulations)
E. Zhou, S. Payne, R. Hofmann, R. Andrews (2015)
Factors affecting lead release in sodium silicate-treated partial lead service line replacementsJournal of Environmental Science and Health, Part A, 50
J. Maynard (2010)
Kinetics of Lead Release from Brass Water Meters and Faucets
(2006)
Compartison of lead contributions from faucets of varying Lead content
D. Lytle, Casey Formal, Kelly Cahalan, Christy Muhlen, Simoni Triantafyllidou (2021)
The impact of sampling approach and daily water usage on lead levels measured at the tap.Water research, 197
Simoni Triantafyllidou, Jonathan Burkhardt, Jennifer Tully, Kelly Cahalan, Michael DeSantis, D. Lytle, M. Schock (2020)
Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocolEnvironment international, 146
(2009)
Investigation of sorptive and desorptive processes between lead and iron corrosion scales in plumbing materials
M. Edwards, Simoni Triantafyllidou (2007)
Chloride‐to‐sulfate mass ratio and lead leaching to waterJournal ‐ American Water Works Association, 99
Abigail Cantor, D. Denig‐Chakroff, Richard Vela, M. Oleinik, D. Lynch (2000)
Use of polyphosphate in corrosion controlJournal ‐ American Water Works Association, 92
(2021)
Evaluating key factors that affect the accumulation and release of Lead from galvanized
(2008)
Pipe loop on steroids! A new approach
(2017)
Internal corrosion control in water distribution systems
(2022)
Benton Harbor -corrosion optimization: Lead solubility study summary
J. Eisnor, G. Gagnon (2003)
A framework for the implementation and design of pilot-scale distribution systemsJournal of Water Supply Research and Technology-aqua, 52
Martyn Shuttleworth (2018)
What is a NOT a Literature Review ?
Kimia Aghasadeghi, S. Peldszus, B. Trueman, Anushka Mishrra, Mitchell Cooke, R. Slawson, D. Giammar, G. Gagnon, P. Huck (2021)
Pilot-scale comparison of sodium silicates, orthophosphate and pH adjustment to reduce lead release from lead service lines.Water research, 195
Damon Roth, H. Baribeau, P. Brandhuber (2021)
Consider the Pros and Cons of Corrosion Testing Methods, 47
H. Reiber, M. Benjamin (1990)
A Multiple Set-Point Polarization Technique for Electrochemical Corrosion Rate Measurement in Potable Water Distribution SystemsCorrosion, 46
C. Yannoni, S. Clark, R. Rafanovic, Covellone, F. Crosby, C. Neff (1995)
Pipe loop demonstration study of corrosion control alternatives at a pH of 10Journal of the New England Water Works Association, 112
TangMin, NystromVictoria, PieperKelsey, ParksJeffrey, LittleBob, GuilliamsRussell, EsquedaThomas, EdwardsMarc (2018)
The Relationship Between Discolored Water from Corrosion of Old Iron Pipe and Source Water ConditionsEnvironmental Engineering Science, 35
Y. Bae, J. Pasteris, D. Giammar (2019)
The Ability of Phosphate To Prevent Lead Release from Pipe Scale When Switching from Free Chlorine to Monochloramine.Environmental science & technology
Abigail Cantor (2009)
Water Distribution System Monitoring: A Practical Approach for Evaluating Drinking Water Quality
D. Macquarrie, D. Mavinic, D. Neden (1997)
Greater Vancouver Water District drinking water corrosion inhibitor testingCanadian Journal of Civil Engineering, 24
(2020)
Impacts of changing from surface water to groundwater on lead behavior - a desk-top and pipe rig case study
(1995)
Elements of a corrosion control study
Evelyne Doré, Elise Deshommes, L. Laroche, Shokoufeh Nour, M. Prévost (2019)
Lead and copper release from full and partially replaced harvested lead service lines: Impact of stagnation time prior to sampling and water quality.Water research, 150
(2018)
Bench-scale testing technical memorandum
J. Clair, Clément Cartier, Simoni Triantafyllidou, Brandi Clark, M. Edwards (2016)
Long-Term Behavior of Simulated Partial Lead Service Line ReplacementsEnvironmental Engineering Science, 33
H. Byars, B. Gallop (1975)
APPROACH TO THE REPORTING AND EVALUATION OF CORROSION COUPON EXPOSURE RESULTS, 14
(2017)
Executive Summary Optimization of Phosphorus-Based Corrosion Control Chemicals Using a Comprehensive Perspective of Water Quality
Aki Kogo, S. Payne, R. Andrews (2017)
Comparison of three corrosion inhibitors in simulated partial lead service line replacements.Journal of hazardous materials, 329
(1981)
Lead pipe test rig design and operation
(2016)
Optimal Corrosion Control Treatment Evaluation Technical Recommendations for Primacy Agencies and Public Water Systems
Bofu Li, B. Trueman, Sebastian Munoz, Javier Locsin, G. Gagnon (2020)
Impact of sodium silicate on lead release and colloid size distributions in drinking water.Water research, 190
Zhijiang Tang, Seungkwan Hong, Weizhong Xiao, James Taylor (2006)
Impacts of blending ground, surface, and saline waters on lead release in drinking water distribution systems.Water research, 40 5
S. Masters, Marc Edwards (2015)
Increased Lead in Water Associated with Iron CorrosionEnvironmental Engineering Science
A. Atassi, A. Putz (2010)
Lake Michigan Utility Tackles Corrosion Control
(2007)
Impact of the change in disinfectant on lead, brass, and copper components in the distribution system
D. Lytle, M. Schock, S. Tackett (1992)
Metal corrosion coupon contamination, corrosion study design, and interpretation problems
J. Patterson, Joseph O'Brien (1979)
Control of Lead CorrosionJournal American Water Works Association, 71
R. Arnold, Jacqueline Rhoades, M. Criswell, Tyson Ingels, W. Becker (2021)
Colorado's Bench‐Scale Lead and Copper Corrosion Testing ProtocolJournal ‐ American Water Works Association, 113
Evelyne Doré, Elise Deshommes, L. Laroche, Shokoufeh Nour, M. Prévost (2019)
Study of the long-term impacts of treatments on lead release from full and partially replaced harvested lead service lines.Water research, 149
S. Reiber, J. Ferguson, M. Benjamin (1988)
An Improved Method for Corrosion‐Rate Measurement by Weight LossJournal American Water Works Association, 80
A. GagnonGraham, D. DoubroughJoelle (2011)
Lead release from premise plumbing: a profile of sample collection and pilot studies from a small system
Brandi Clark, J. Clair, M. Edwards (2015)
Copper Deposition Corrosion Elevates Lead Release to Potable WaterJournal ‐ American Water Works Association, 107
M. Edwards, A. Dudi (2004)
role of chlorine and chloramine in corrosion of lead‐bearing plumbing materialsJournal ‐ American Water Works Association, 96
Clément Cartier, Evelyne Doré, L. Laroche, Shokoufeh Nour, M. Edwards, M. Prévost (2013)
Impact of treatment on Pb release from full and partially replaced harvested Lead Service Lines (LSLs).Water research, 47 2
(2016)
NSF international standard/American National Standard 61: Drinking water system components-health effects
(2004)
Standard practice for laboratory immersion corrosion testing of metals
(1995)
Measuring corrosion rates in drinking water by linear polarization -assumptions and watchouts
S. Masters, Jeffrey Parks, A. Atassi, M. Edwards (2016)
Inherent variability in lead and copper collected during standardized samplingEnvironmental Monitoring and Assessment, 188
(1996)
Corrosion assessment technologies. In internal corrosion of water distribution systems
(2020)
Comparing Estimated Impacts of OCCT and Lead
(1994)
Development of pipe loop protocol for Lead control
Bench top and pilot lead corrosion studies are gaining more interest, considering revisions and upcoming improvements to the Lead and Copper Rule. This literature review identified studies ranging from simpler month(s)‐long bench top dump‐and‐fill stagnant water tests (coupon tests/standing pipe tests) to more complicated year(s)‐long intermittent flow pilot studies (recirculating pipe loops/once through pipe rigs). With increasing complexity in design and operation, studies more closely approximated real plumbing conditions (e.g., by incorporating harvested lead pipes and intermittent flow regimes) at increased cost, footprint, and duration. Comparison of bench top and pilot designs (in terms of lead test piece age/dimensions/configuration/replicates, study duration, sample collection, and other factors) can assist drinking water utilities, consultants, academics, and others to select a design that matches their needs and constraints. No matter the choice, surrogate systems cannot replace actual system water testing and are best complemented by other corrosion assessment tools.
AWWA Water Science – Wiley
Published: Mar 1, 2023
Keywords: coupon and standing pipe test; lead; once through pipe rig; recirculating pipe loop
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.